HVAC/R Equipment Select
HVAC
Application & Category
Model & Condition
Select all symptoms observed
Superheat & Subcooling calculator
Enter pressures and temperatures above.
Airflow & Static Pressure Estimator
Enter values above.
Tonnage / Capacity Verification
Enter values above.
Refrigerant Charge Estimator
Enter values above.
Refrigerant saturation pressure / temperature reference
Refrigerant40°F sat (PSIG)105°F sat (PSIG)SH targetSC targetGWPClassNotes
R-2268.522610–15°F10–15°F1810A1 legacyPhased out — recover, never vent
R-410A118.239310–15°F10–15°F2088A1High-pressure gauges required
R-321173808–12°F8–12°F675A2LMildly flammable — A2L protocols
R-454B1143688–12°F8–12°F466A2LPuron Advance / EcoFlex (2025+)
R-407C5519610–15°F10–15°F1774A1R-22 drop-in (approximate)
R-134a35.117110–20°F10–15°F1430A1Coolers, chillers, automotive
R-404A87.22958–12°F6–10°F3922A1 HGWPhasedown underway — high GWP
R-448A893018–12°F6–10°F1387A1R-404A replacement (Solstice N40)
R-449A852908–12°F6–10°F1282A1R-404A / R-22 retrofit option
R-29070.224010–15°F8–12°F3A3 HCMax 150g — no ignition sources
R-600a17.57010–15°F8–12°F3A3 HCHousehold fridges — combustible detector
R-744 (CO2)4991466variesvaries1A1Transcritical — 1500+ PSIG possible
Field targets by system type
ParameterResidential A/CHeat pumpLight commercialWalk-in / display
Superheat (TXV)8–12°F8–12°F8–12°F8–12°F
Superheat (fixed orifice)10–18°F10–18°F10–18°FN/A
Subcooling10–15°F10–15°F10–15°F6–10°F
Supply air ΔT (cooling)17–22°F17–22°F17–22°F
Supply air temp (HP heat)90–110°F90–110°F90–110°F
Airflow per ton350–400 CFM350–400 CFM350–450 CFM
Max TESP residential0.5 in. w.c.0.5 in. w.c.0.8–1.0 in. w.c.
Evap coil temp (A/C)35–45°F35–45°F35–45°F10–25°F med-temp
Condenser splitAmb +25–30°FAmb +25–30°FAmb +25–30°FAmb +20–30°F
Cooler case target34–38°F
Freezer case target-10 to 0°F
Flame sensor hold-in µA0.5–4.0 µA DC
Gas valve voltage24V AC ±10%
Glycol chiller setpoint26–28°F26–28°F
CO2 pressure (dispenser)90–100 PSI
Syrup / BIB pressure70–80 PSI
Error codes — residential & light commercial
BrandCodeMeaningFirst check
Carrier / BryantE1Low pressure lockoutRefrigerant charge, TXV, filter-drier
Carrier / BryantE2High pressure lockoutCondenser fan, coil fouling, overcharge
Carrier / BryantE3Freeze protection tripAirflow, low charge, coil temp sensor
Carrier / BryantE6Communication faultThermostat wiring, C wire, control board
Trane / Am. Standard126High pressure tripCondenser fan, refrigerant overcharge
Trane / Am. Standard179Low pressure tripRefrigerant leak, TXV stuck closed
LennoxE077High pressure lockoutCondenser coil, airflow restriction
LennoxE080Low pressure lockoutRefrigerant charge, TXV
LennoxE221Freeze protectionCoil temp sensor, airflow
York / Johnson4 blinkHigh pressure cutoutCondenser fan, fouled coil
York / Johnson6 blinkLow pressure cutoutLow charge, TXV stuck
Goodman / Amana3 flashPressure switch openFilter, inducer motor, flue blockage
Goodman / Amana4 flashOpen high-limitAirflow, blower motor, filter
Goodman / Amana6 flashRollout switch openHeat exchanger crack, flue obstruction
Rheem / Ruud5 flashFlame sensor faultFlame sensor dirty, gas valve
Rheem / Ruud6 flashIgnition lockoutGas supply, igniter, flame sensor
DaikinE7Outdoor fan faultFan motor, capacitor, control board
DaikinU4Communication errorIndoor/outdoor wiring, PCB
MitsubishiE6Communication errorSignal wire polarity, PCB
MitsubishiP8Outdoor unit faultRefrigerant charge, outdoor PCB
LG Mini-splitCH01Indoor temp sensorSensor resistance vs temp chart
LG Mini-splitCH10Communication errorSignal wiring, control boards
FujitsuE:EEEEPROM faultReplace indoor PCB
SamsungC4-00Communication faultSignal wiring, indoor/outdoor boards
Thermostat wiring — standard color codes
TerminalColorFunctionNotes
R / Rh / RcRed24V power (hot)Rh = heat transformer · Rc = cool transformer
CBlack or BlueCommon (24V return)Required for smart / wifi thermostats
Y / Y1YellowCompressor / cooling stage 1Energizes contactor coil
Y2Yellow/darkCompressor stage 2Two-stage compressor only
GGreenIndoor fan (blower)Fan-only / circulation mode
W / W1WhiteHeat stage 1Gas valve or aux heat strip
W2 / AuxWhite/stripeHeat stage 2 / auxElectric backup or 2nd-stage gas
OOrangeReversing valve (energize = cool)Carrier, Trane, most brands
BBlueReversing valve (energize = heat)Some older Rheem / York heat pumps
E / EmGrayEmergency / aux heatBypasses compressor lockout
Mini-split line set sizing & flare torque
CapacityLiquid line ODSuction line ODTorque (liquid)Torque (suction)Max run
Up to 9k BTU (0.75T)1/4"3/8"10–13 ft-lb14–18 ft-lb25 ft
12k–18k BTU (1–1.5T)1/4"1/2"10–13 ft-lb25–33 ft-lb50 ft
24k BTU (2T)3/8"5/8"14–18 ft-lb33–40 ft-lb65 ft
36k BTU (3T)3/8"5/8"14–18 ft-lb33–40 ft-lb98 ft
48k+ BTU (4T+)1/2"3/4"25–33 ft-lb40–50 ft-lbPer mfr
Dispenser Selection
Install Parameters
Select all symptoms observed
Account & Equipment
Site Conditions
Select all symptoms observed
System Configuration
Routing Parameters
Select all symptoms observed
Freestyle Unit Selection
Site Conditions
Select all symptoms observed
Equipment Type
Model & Condition
Select all symptoms observed
Machine Type & Brand
Unit Condition
Select all symptoms observed
FIELDTECH AI
Select a context above then ask me anything — diagnostics, refrigerant specs, wiring, error codes, parts, repair procedures, or field calculations. I give practical job-site answers.